RB iconIP iconMPE iconRBAS iconRouse icon

CAT SR4B-GD

السعر من دون ضريبة القيمة المضافة

Favoriteالمفضلة
shareحصة
Save searchحفظ عملية البحث
طباعة

المعلومات

مجموعة المنتجات
مولدات ديزل
الماركة/الطراز
CAT SR4B-GD
سنة الصنع
2012
خيارات إضافية
معدات مستخدمة
موقع الماكينة
Langley، British Columbia
البلد
كندا
Mascus ID
5408F2EF

السعر

اختيار عملة

تفاصيل

رقم المخزون الداخلي
138143
معلومات أخرى
1843 kVA 1475 kW Natural Gas Generator SR4B-GD w/ Engine 3516C Title: 1843 kVA 1475 kW Natural Gas Generator SR4B-GD w/ Engine 3516C SKU: 138143 Model: SR4B-GD Year: 2012 Condition: Used S/N: G5Z01287 GeneralHorsepower:1978hp Fuel Type:Natural Gas Hours:27582.4 ElectricalkVA:1843kVA Voltage:400volts Phase:3-phase Made In: UNITED STATES Dimensions: 122.00 (H) x 118.00 (W) x 480.00 (L) inches Overhaul done at 26210 hours Ran for 1300 hours after overhaul Currently set for 50hz but can bump frequency up to 60hz Engine: - Caterpillar 3516C - Advertised power: 1622 kW // 2175 hp - Full load speed: 1500 RPM - Comp. ratio: 11.3:1 Overhaul Job Description: - Engine Major Overhaul - The cylinder block of generator set NO.5 is installed - Replaced main and rod bearings, piston rings, thermostat, and other wear parts - Replaced all seals on the unit; -Replaced 16 pistons and 4 cylinder liners - Repaired the cylinder head, parts not replaced; -Replaced two water pumps with REMAN parts - Repaired the oil pump - Cleaned and pressured test the oil cooler - Visually inspected the turbocharger. Left turbocharge used again, right turbocharge to be repaired - The coupling has been damaged and continues to be used without replacement Generator Maintenance: - It used the generator of the NO 5 genset set after maintenance - Replaced front and rear bearings and grease seals - Replaced front and rear bearing outer rings - Performed laser cladding on the rear ends of the main shaft - Performed VPI (Vacuum Pressure Impregnation) insulation treatment and drying - Conducted rotor dynamic balance test - Conducted overall performance testing Shaft Alignment Check: - Engine and Generator Shaft Alignment Radiator Check: - The water tank of genset 5 was installed into genset 6 - Radiator Disassembly, Reassembly, and Cleaning Generator Set D&A: - Continued to use the container of generator Set 6 - Generator Set Entry and Exit from the Container Overall Performance Testing: - Tested according to Caterpillar test standard 349-6498 (see attachment for details), with a maximum load reaching 60%. As all cylinder heads installed are manually refurbished on site, please note that the long-term load must not exceed 60%عرض المزيد

Lenmark Industries Ltd

27576 51a Ave V4W 4A9 Langley British Columbia كندا
1
سنة نشط علي ماسكوس
الحصول على إشعار عبر البريد الإلكتروني
report adالإبلاغ عن إعلان مريب